Blue Icon (Tianjin) Technology Co., Ltd.
Blue Icon (Tianjin) Technology Co., Ltd.
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)
  • BIT-PT850 Outdoor Variable Speed Heavy Duty Pan Tilt Head with Payload up to 50kg (110.23lb)

Positioner i førerstilling i førerstilling med høj præcision i førerstilling Max. 50kg (110.23lb) In

Egenskaber for BIT-PT850 Yderst variabelt Heavy Speed Duty Pan Tilt Head med Paytload op til 50kg (110.23lb)

  • Maksimal belastningskapacitet 50kg (110Hastighed 0.1§15176;/ s

  • Præcision: 1770adaptiv hastighed til zoomat

  • Støtteanalog eller netværkskamera

  • Antikorrosionsoverfladebehandling

  • Nomined IP66 for støvbeskyttelse og beskyttelse af vandindsugning


Oversigt over BIT-PT850 Udendørs variable Heavy Speed Heavy Duty Pan Tilt Head


BIT-PT850 heavy duty pan vippe enhed er en stor pan med belastningskapacitet op til 50kg (110.23lb).Den er drevet af AC/DC24V.Via Pelco-protokollen, RS4885-interface, kan den kontrolleres af indlæste kameraer eller en joystick controller.Fremstillet af støbealuminiumslegering med yderligere korrosionsoverfladebehandling, er IP66-afskærmning og ideelt til et langdistance pan vippe-zoom-system, der anvendes i mange kritiske områder såsom lufthavn, søhavn, militær infrastruktur, og også til brug i byer, strandskibe.



Tekniske specifikationer for BIT-PT850 Heavy Duty Pan Tilt Head



Model

BIT-PT850

Max. Load Capacity

50kg (110.23lb), top load

Load Type

Indoor/outdoor, top load

Pan Angle

Pan: continuous 360°

Tilt Angle

+45°~-45°(load capacity 50kg) Default


-60°~+60°(load capacity 40kg)


-80°~+80°(load capacity 26kg)

Rotation Speed

Pan: 0.01°/s-30°/s
Tilt: 0.01°/s-15°/s

Programmable Presets

200

Preset Accuracy

± 0.1°

Cruising Track

8

Scan

8

Coordinate Feedback

Support angle query feedback or real-time feedback

Absolute Control

Support

Lens Preset

Support

Lens Control Speed

Continuously adjustable zoom, focus speed

Adaptive PT Speed to Zoom

Speed up while zooming out, slow down while zooming in

Guard Location

Support with 1 preset or 1 cruising track or 1 auto scan

Power Failure Memory

Support, recover to PT position, scan/preset/cruising track movement before power failure



Self-lock

Support

Protocol

Pelco P/D

Baud Rate

2400/4800/9600/19200 bps

Communication Interface

RS485 (Optional RS422) or RJ45

Transmission

Worm gear transmission

General

Operating Voltage

AC24V±25 %, 50/60Hz or DC24V±10 %

Power Consumption

≤100W (With heater)

Working Temperature  ( with heater)

-40ºC~+60 ºC (-40 ºF ~ 140 ºF)

Working Humidity

90±5% RH

Storage Temperature

-40 ºC~+70 ºC (-40 ºF ~ 158 ºF)

Protection Level

IP66

Material

Aluminium Alloy

Weight

23kg (50.7lb)

Dimension  (L×W×H)

224×341×403mm (8.81x12.42x15.864in)




Video


Dimension BIT-PT850 Heavy Duty Pan Tilt Head


outdoor-variable-speed-heavy-duty-pan-tilt-head.jpg


Unit: mm



FAQ for BIT-PT850 Heavy Duty Pan Tilt Head

  • Hvad er standardkontrolprotokol, adresse og bautate af BIT-PT850's sværvægter med vippehoved-positioner?

    Standard som, Pelco D, adresse: 1, bauate: 9600.

    Følg brugervejledning8217s og ændr dem på skiftepanelet på pan- vippen efter fjernelse af omslaget.


  • Hvad er IP-rating og 8220; IP66-beskyttelse af indtrængen 8221; i BIT-PT850 kraftige hældningsenheder?

    IP-rating er også kendt som Ingeress Protection eller International Protection ratings er defineret i den internationale standard EN 60529 (British BS EN 60529:1992).Denne standard anvendes til at definere graden af forseglingseffektivitet af elektriske anlæg mod indtrængen fra fremmedlegemer såsom værktøj, snavs og fugt.


    BIT-PT850 haevy duty pan har en IP66-beskyttelse mod indtrængen.Nedenfor gives en redegørelse for IP66-rating:

    beskyttet mod total indsugning af støv.

    Beskyttet mod højtrykvandsfly fra enhver retning.


  • Vil BIT-PT850 være i stand til at arbejde i et omkostningsmæssigt miljø?

    Det er velkendt, at saltvand i costal-området ætser metal i kystmiljøer, så for at forlænge den arbejdsdygtige tid for pan-vippe-positioneringsenhed, tilbyder vi en yderligere opløsning med korrosionsbestandig overfladebehandling og overtrækspulver på BIT-PT850 heavy pan vippe enhed.


  • Hvad er 8220; Guard Sted 8221; funktion i BIT-PT850 sværvægter vippehoved positioner?

    Hvis BIT-PT850 pan- vippeenheden ikke 8217t; t modtager nogen styringskommandoer for en vis mængde forudindstillet tid, vil den begynde at køre en vis forudindstillet bevægelse som forudindstilling, krydsning eller autoscanning.


Leave us Message

Tilknyttet Heavy Duty Pan Tilt Head/Units